FP 400
Temperature test chamber with forced convection

FP 240

FP series chambers are designed for the most demanding test applications and are particularly effective, thanks to their extensive programming abilities. The forced convection reliably facilitates quick drying times as well as extra rapid heating-up, even with fully loaded chambers.

  • Electronically controlled APT.line™ preheating chamber assuring temperature accuracy and reproducible results
  • Temperature range 5 °C (9 ºF) above ambient temperature up to 300 °C (572 °F)
  • MP Controller, 2 programs with 10 sections each or alternatively switch over to 1 program with 20 sections
    - The time interval of single program sections can be adjusted up to a maximum of 99:59 hours or 999:59 hours. This adjustment applies to all program sections
    - Integrated week program timer with real time function
    - Adjustable time functions and programmable temperature ramp function via program editor
  • Digital temperature setting with an accuracy of one degree
  • Adjustable fan speed
  • Adjustable front ventilation flap slide and rear exhaust ø 50 mm (1.97 inch)
  • Elapsed time indicator
  • Independent adjustable temperature safety device class 2 (DIN 12880), with visual temperature alarm
  • RS 422 interface for use with optional GMP/GLP and FDA guideline 21 CFR Part 11 compliant APT-COM™ DataControlSystem software, or switch over to printer output with RS 232 / RS 422 interface converter
  • Units up to 115 liters are stackable
  • 2 chrome-plated racks included
  • BINDER test certificate

 

 

 

Technical Specifications

 

Exterior dimensions

 

Width (mm/inch)

1234 / 48.6

Height (inclusive feet) (mm/inch)

1022 / 40.2

Depth (mm/inch)

765 / 30.1

plus door handle and exhaust duct (mm/inch)

90 / 3.5

Wall clearance rear (mm/inch)

100 / 3.9

Wall clearance side (mm/inch)

160 / 6.3

Exhaust duct outer- Ø (mm/inch)

52 / 2.1

Steam space volume (l/cu.ft.)

498 / 17.6

Number of doors

2

Interior dimensions

 

Width (mm/inch)

1000 / 39.4

Height (mm/inch)

800 / 31.5

Depth (mm/inch)

500 / 19.7

Interior volume (l/cu.ft.)

400 / 14.3

Racks, chrome-plated (number standard/max.)

2 / 10

Load per rack (kg/lbs.)

35 / 77

Permitted total load (kg/lbs.)

90 / 199

Weight of the unit (empty) (kg/lbs.)

145 / 320

Temperature data

 

Temperature range, 5 °C (41 °F) above ambient up to (°C / °F)

300 / 572

Temperature variation 1)

 

at 70 °C (± °C)

1

at 150 °C (± °C)

2.5

at 300 °C (± °C)

4.8

Temperature fluctuation (± °C)

0.3

Heating up time 2)

 

to 70 °C (Min.)

18

to 150 °C (Min.)

35

to 250 °C (Min.)

60

Recov. time after door was opened for 30 sec. 2)

 

at 70 °C (Min.)

2

at 150 °C (Min.)

17

at 300 °C (Min.)

21

Air change data

 

Air change

 

at 70 °C (x/h)

17

at 150 °C (x/h)

18

at 300 °C (x/h)

16

Electrical data

 

Housing protection acc. to EN 60529

IP 20

Nominal voltage (±10 %) 50 / 60 Hz (V)

400 / 3 N~

Nominal power (kW)

3.4

Energy consumption

 

at 70 °C (W)

520

at 150 °C (W)

1200

at 300 °C (W)

2340

 

 

 

Contact us on 01939 291200 or by email info@sciquip.co.uk