FRIOCELL with forced air convection and cooling

The high technical standard of our FRIOCELLincubators allows exact incubation processes both for variation and deviation. The units have very short recovery times and show an excellent manner in keeping the precise regulation. A unique cooling system ensures, that the samples are not dried while cooling. A high performance system of lighting ensures outstanding homogenous parameters for tests and growth conditions. These devices are designed for use in biotechnology, botany, food processing industry, cosmetics, chemical industry etc.
- Volume: 22, 55, 111, 222, 404, 707 litres
- Working temperature:
INCUCELL:
0 °C up to 99.9 °C, FC 22: +5 °C up to 70 °C
(option –9,9 °C) - Refrigerant:
R 134a (FC 22 without refrigerant) - Inner glass door
Interior:
stainless steel, mat. No. 1.4301 (AISI 304)
The high-tech comfort line with multi-functional microprocessor control unit

- 6 programs
- chip card system for individual program storage
- RS 232- interface for printer or PC-communication
- delayed heating start and stop function
- acoustic and visual alarm
- time range 0–16 years with 1 min-intervals
- digital safety thermostat class 3
- real time
- programming temperature ramps
- heating sequences
- programme cycles
- adjustable ventilation rate 10 to 100 % (FC 22 only 100 %)
Options
- –9,9 °C with cooled incubators
- interior lighting – a wide offer of various luminary sources
- access ports ? 25, 50, 100 mm (? 100 mm is not available for 22-litres volume)
- keyboard lock (prevents the access of unauthorised persons)
- automatic door lock
- left door versions (excluded volume 22, 404 and 707 liters)
- timer programmable water protected inner socket
- exposure/stimulating lighting (white/day light)
6 000–13 000 Lx (according to volume) with
digitally adjustable light
10–100 % - exposure illumination in shelves, especially for photo-stability tests (according to ICH Guideline CPNP/ICH279/95)
- potential-free alarm contact
- measurement of material´s temperature with an independent movable sensor PT 100 (with indication on a display or PC)
- communication software WarmComm
- stainless steel casing of the device
Specifications
|
Model |
22 |
55 |
111 |
222 |
404 |
707 |
|
Inner dimensions
|
volume |
l |
22 |
55 |
111 |
222 |
404 |
707 |
width |
mm |
244 |
400 |
540 |
540 |
540 |
940 |
|
depth |
mm |
307 |
370 |
370 |
520 |
520 |
520 |
|
height |
mm |
296 |
350 |
530 |
760 |
1410 |
1410 |
|
Volume of the steam space |
|
l |
43 |
89 |
163 |
299 |
524 |
876 |
Trays, stainless steel *) |
number |
max./usual |
4/2 |
4/2 |
7/2 |
10/2 |
19/2 |
19/2 |
Min. distance between trays |
|
mm |
60 |
70 |
70 |
70 |
70 |
70 |
Storage area |
(w x d) |
mm |
185x265 |
380x335 |
520x338 |
520x485 |
520x485 |
920x485 |
Number of outer metal doors |
|
No |
1 |
1 |
1 |
1 |
1 |
2 |
Number of inner glass doors |
|
No |
1 |
1 |
1 |
1 |
1 |
2 |
Admissible weight of trays together inside the oven |
|
kg |
25 |
50 |
50 |
70 |
100 |
130 |
Admissible weight of trays per 1tray |
|
kg |
10 |
20 |
20 |
30 |
30 |
50 |
Electricity data |
||||||||
|
max. power consumption |
W |
100 |
990 |
990 |
990 |
1590 |
1690 |
|
mains 50/60 Hz |
V |
100-240 |
230 |
230 |
230 |
230 |
230 |
Protective system |
|
|
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
IP20 |
Temperature data |
||||||||
Working temperature |
from 0 °C |
to °C |
+5 °C – +70 °C |
99,9 |
99,9 |
99,9 |
99,9 |
99,9 |
Temperature accuracy |
||||||||
in space at 10 °C |
|
± °C |
< 0,3 |
< 0,5 |
< 0,5 |
< 0,5 |
< 1 |
< 1 |
in space at 37 °C |
|
± °C |
< 0,3 |
< 0,5 |
< 0,5 |
< 0,5 |
< 1 |
< 1 |
in time |
|
± °C |
< 0,1 |
< 0,2 |
<0.2 |
<0.2 |
<0.3 |
<0.4 |
Heating/up time to 37 °C from the ambient temperature |
min |
<10 |
23 |
24 |
25 |
26 |
27 |
|
Cooling/down time from 22 °C to 10 °C |
|
min |
<33 |
<21 |
<21 |
<21 |
<21 |
<21 |
Recovery time at 37 °C after 1 min. door open |
|
min |
1,5 |
4 |
4 |
4 |
4 |
4 |
Recovery time at 50 °C after 1 min. door open |
|
min |
4 |
4 |
4 |
4 |
4 |
4 |
Relative humidity |
range |
% |
10–90 |
10–90 |
10–90 |
10–90 |
10–90 |
10–90 |
Heat emission |
at 37 °C |
W |
50 |
62 |
70 |
97 |
123 |
148 |
Outer dimensions (incl. door and handle, and Rollers) |
width |
max. mm |
406 |
620 |
760 |
760 |
1010 |
1460 |
depth |
max. mm |
592 |
640 |
640 |
790 |
790 |
790 |
|
height |
max. mm |
605F |
820F |
1000F |
1230F |
1910R |
1910R |
|
Weight
|
netto |
kg |
33 |
80 |
101 |
132 |
230 |
270 |
brutto |
kg |
38 |
99 |
131 |
169 |
270 |
316 |
|
*) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber.
Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing.
Changes in the design and make reserved..