VENTICELL with forced air convection

Due to a patented ventilation system the air within the VENTICELL-chamber is ventilated in a regular spiral way. This leads to a homogenous temperature profile throughout the chamber and short heating times. Operating economy is ensured by higher rate and precision of heating in laboratories. Especially suitable for very moist goods.

  • Volume:
    22, 55, 111, 222, 404, 707 litres
  • Working temperature:
    10 °C above ambient temperature up to 250/300 °C
  • Interior:
    stainless steel, mat. No. 1.4301 (AISI 304)

 

 

 

 

 

 

 

The versatile standard line with microprocessor control unit
  • 3 programs
  • RS 232- interface for printer or PC-communication
  • delayed heating start and stop function
  • acoustic and visual alarm
  • time range 99 hours 59 minutes
  • digital safety thermostat class 2
  • manual control of the suction flap and the air exhaust flap

 

 

Options
  • door window and interior lighting (excluded volume 22 litres)
  • access ports ø 25, 50, 100 mm (ø 100 mm is not available for 22-litres volume)
  • door lock
  • left door versions (excluded volume 22 and 707 litres)
  • communication software WarmComm
  • HEPA - filter for installation in air inlet
  • two-door (passing through) version (possible only by types with volume 222, 404 and 707 litres)
  • temperature range anlargement up to 300 °C
  • stainless steel casing of the device
  • measurement of material´s temperature with an independent movable sensor PT 100
    (with representation on a display or PC)

 

The high-tech comfort line with multi-functional microprocessor control unit
  • 6 programs
  • chip card system for individual program storage
  • RS 232- interface for printer or PC-communication
  • delayed heating start and stop function
  • acoustic and visual alarm
  • time range 0–16 years with 1 min-intervals
  • digital safety thermostat class 2
  • real time
  • programming temperature ramps
  • heating sequences
  • programme cycles
  • adjustable ventilation rate 10 to 100 %
  • manual control of the suction flap and the air exhaust flap

 

Options
  • door window and interior lighting (excluded volume 22 litres)
  • acess ports ø 25, 50, 100 mm (ø 100 mm is not available for 22-litres volume)
  • door lock
  • left door versions (excluded volume 22 and 707 litres)
  • communication software WarmComm
  • HEPA-filter for installation in air inlet
  • potential-free alarm contact
  • measurement of material´s temperature with an independent movable sensor PT 100
    (with representation on a display or PC)
  • two-door (passing through) version (possible only by types with volume 222, 404 and 707 litres)
  • temperature range anlargement up to 300 °C
  • stainless steel casing of the device

 

Specifications

 

 

Model

22

55

111

222

404

707

Interior of stainless steel material No. 1.4301

volume

cca ltrs

22

55

111

222

404

707

width

cca mm

240

400

540

540

540

940

depth

cca mm

320

390

390

540

540

540

height

cca mm

295

350

530

760

1410

1410

Trays

 

 

 

racks

max. No.

4

4

7

10

19

19

standard equipment

pcs. included

2

2

2

2

2

2

distance between guide rails

mm

60

70

70

70

70

70

storage area (w x d)

mm

185x265

380x335

520x335

520x485

520x485

920x485

Maximal weight of the load*)

 

per tray

max. kg

10

20

20

30

30

50

inside the oven

max. kg

25

50

50

70

100

130

Door

 

No.

1

1

1

1

1

2

External dimensions (including door and handle)

 

 

 

width

cca mm

406

620

760

760

760

1160

depth

cca mm

560s/580c

640

640

790

790

790

height (incl. Foots and Rolls)

cca mm

604F

680F

860F

1090F

1910R

1910R

diameter of the air branch outer/inner

cca mm

52/49

52/49

52/49

52/49

52/49

52/49

Package dimensions (three layers carton)

 

 

width

cca mm

465

700

830

830

830

1230

depth

cca mm

665

730

730

860

860

860

height (incl. palette)

cca mm

655

880

1050 

1280

2070

2080

Weight

 

netto

max kg

31

55

75

100

150

215

brutto

max kg

36

66

87

116

175

240

Working temperature (beginning of the regulation) **)

 

from 10°C above ambient temp. to °C 

250/300

250/300

250/300

250/300

250/300

250/300

Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door, >50°C  

space deviation

cca ( ±)% °C of the reached temperature

1,2

1

1

1

1,5

2,5

time variation

cca ± °C

0,3

0,4

0,4

0,4

0,4

0,4

Time required to reach 250 °C with closed air flap and voltage 230 V

 

cca min.

28

49

53

70

58

64

Heat emission at
250 °C

 

cca W

350

590

760

990

1940

2550

Air exchange speed at 150 °C

 

cca/hour

45

45

49

24

18

12

Electricity -mains 50/60 Hz

 

 

 

max. power input

cca kW

0,96

1,3

1,9

1,9

3,7

4,9

stand by

cca W

5

5

5

5

5

5

current

A

4,2

5,7
11,3

8,3
16,5

8,3
16,5

5,7; 5,2; 5,2 9,5; 9,9
19,1; 18,1; 18,1

5,7; 5,2; 10,4 11,9; 13,5; 11,4 23,8; 27,1; 22,8

nominal voltage

V

230
115

230
115

230
115

230
115

3x400+N+PE 3x230
3x115

3x400+N+PE 3x230
3x115

 

*) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber.

**) Standard type is up to 250 °C, optional type is up to 300 °C.

Note: All technical data are related to 22 °C ambient temperature and ± 10 % voltage swing (if not specified). Changes in the design and make reserved.