Climacell Environmental Test Chamber with forced air convection, cooling and controlled humidity

The CLIMACELL series was specially developed for applications, in which as far as possible exact and reproducible simulation of various environmental conditions is important, e.g. stability testing of components, packaging materials, food or chemicals, germination studies, plant cell or tissue cultures, insect cultures.

  • Volume: 111, 222, 404, 707 litres
  • Working temperature: without humidity 0 °C up to 99.9 °C, with humidity: 10 °C up to 90.0 °C
  • Refrigerant: R 134a
  • Water quality for generating the humidity: distilled water, drinking water (max. 50 mg Ca/l)
  • Controlled humidity: 10 %–90 % RH
  • Microprocessor controlled humidifying/ /dehumidifying system
  • Inner glass door Interior: stainless steel, mat. No. 1.4301 (AISI 304)

 

 

 

The high-tech comfort line with multi-functional microprocessor control unit
  • 6 programs
  • chip card system for individual program storage
  • RS 232- interface for printer or PC-communication
  • delayed heating start and stop function
  • acoustic and visual alarm
  • time range 0-16 years with 1 min-intervals
  • digital safety thermostat class 3
  • real time
  • programming temperature ramps
  • heating sequences
  • programme cycles
  • adjustable ventilation rate 10 to 100 %

 

Options
  • –9,9 °C with cooled incubators
  • interior lighting – a wide offer of various luminary sources
  • access ports ? 25, 50,100 mm
  • keyboard lock (prevents the access of unauthorised persons)
  • automatic door lock
  • left door versions (excluded volume 404 and 707 liters)
  • timer programmable water protected inner socket
  • exposure/stimulating lighting (white/day light) 6 000–13 000 Lx (according to volume) with digitally adjustable light 10–100 %
  • exposure illumination in shelves, especially for photo-stability tests (according to ICH Guideline CPNP/ICH279/95)
  • potential-free alarm contact
  • measurement of material´s temperature with an independent movable sensor PT 100 (with indication on a display or PC)
  • communication software WarmComm
  • check of the door opening (microswitch) during the program with the possibility of the record by means of a printer or software
  • stainless steel casing of the device

 

Specifications

Inter dimensions Chamber, stainless steel

Model

111

222

404

707

Inter dimensions Chamber, stainless steel

 

 

 

volume

l

111

222

404

707

width

mm

540

540

540

940

depth

mm

370

520

520

520

height

mm

530

760

1410

1410

Volume of the steam space

 

cca l

163

299

524

876

Trays, stainless steel *)

number

max./usual

07-Feb

10-Feb

19-Feb

19-Feb

Min. distance between trays

 

mm

70

70

70

70

Storage area

(w x d)

mm

520x338

520x485

520x485

920x485

Number of outer metal doors

 

No

1

1

1

2

Number of inner glass doors

 

No

1

1

1

2

Admissible weight of trays together inside the oven

 

kg

50

70

100

130

Admissible weight of trays per 1tray

 

kg

20

30

30

50

Electricity data

 

max. power consumption

W

2050

2100

3150

3400

 

mains 50/60 Hz

V

230

230

230

230

Protective system

 

 

IP20

IP20

IP20

IP20

Temperature data

Working temperature

from 0 °C

to °C

99,9

99,9

99,9

99,9

Temperature accuracy

 

 

 

 

 

 

in space at 10 °C

 

± °C

< 0,5

< 0,5

< 1

< 1

in space at 37 °C

 

± °C

< 0,5

< 0,5

< 1

< 1

in time

 

± °C

< 0,2

< 0,2

<0.3

<0.4

Heating/up time to 37 °C from the ambient temperature

 

min

24

25

26

27

Cooling/down time from 22 °C to 10 °C

 

min

<21

<21

<21

<21

Recovery time at 37 °C after 1 min. door open

 

min

4

4

4

4

Recovery time at 50 °C after 1 min. door open

 

min

4

4

4

4

Relative humidity

range

%

10–90

10–90

10–90

10–90

Heat emission

at 37 °C

W

70

97

123

148

Outer dimensions (incl. door and handle, and Rollers)

width

max. mm

760

760

1010

1460

depth

max. mm

640

790

790

790

height

max. mm

1100R

1330R

1910R

1910R

Weight

 

netto

cca kg

101

132

230

270

brutto

cca kg

131

169

270

316

 

*) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22 °C of ambient temperature and ±10 % voltage swing Changes in the design and make reserved.